Procurement of Pathological/Laboratory items (投標 №88137686cn)

請註冊

分享這個:
國家: India
語言: EN
數: 88137686
出版日期: 27-07-2023
源:

描述

有關招標的全部信息已關閉。
有關該站點的更多信息,請閱讀以下信息。

關於我們

俄羅斯和世界範圍內招標和採購的領先搜索引擎

  • 俄羅斯和世界上最大的招標和採購來源數據庫
  • 根據您的設置免費提供每日新聞
  • 您需要的格式的中標者信息
  • 方便顯示和上傳信息

選擇我們

入門

在站點上註冊,之後您可以使用以下站點功能:

  • 為您的關鍵短語訂閱免費郵件列表
  • 查看招標公告
  • 以Excel格式導出摘要信息
  • 查看有關標書的中標者,供應商和客戶的部分信息

登記表

要使用網站的所有功能並查看全部信息,您需要註冊一個商業帳戶

  • 選擇關稅
  • 以任何可能的方式付費進行訪問

完全訪問
Tenders are hereby invited for the following: Supply of air spring. Specification: - Air Spring, vehicular, type: air bellow, P/N: T21077672, wear and tear, unserviceable part, Qty: 08. Please note that this quotation was published late. 源: ONLINE TENDERS

Re-Advertisement: Quotations are hereby invited for the following: Sany ECH008 & ECH009 Corrosion Protection. Scope: - Any cracks/defective welds found, are to be treated, applying anti corrosion primer, intermediate and final coat (As per Transnet Corrosion Protection EEAM-Q-008 rev 17). NDT reports that depict a "failed" result is to be repaired and subjected to re-testing until a "pass/satisfactory" result is obtained. A welding procedure specifically for the repairs of cracks is to be provided by the Contractor to the employer representative"s acceptance. Alternate NDT tests (ie. Crack test) are to be conducted on stress points of the ECH and be submitted to the employee in the Data pack. - Welding is to be performed by a coded / certificated welder. - Thickness testing to be conducted on spreader channels, lifting hooks, cabin arrangement (interior, exterior, roof, guards and balance weight, guard plates, side mirror mounting brackets sections where excessive corrosion is encountered. Affected areas to be replaced where the thickness has deteriorated to below 70% of the original parent metal thickness, or where cracks have been detected on the affected area. (Proof to be submitted in Data Pack). - Corrosion protection to be conducted on corroded areas along the whole structure and miscellaneous areas surrounding these, which includes spreader channels, lifting hooks, cabin arrangement (interior, exterior, roof, guards and balance weight, guard plates, side mirror mounting brackets, all hinges, mounting pins, hydraulic cylinder barrels. - The handrails, access staircases, platforms, shall be removed, repaired and sent for Sandblasting and hot galvanized prior to installation (As per Transnet Corrosion Protection EEAM-Q-008 rev 17). All corroded handrails are to be repaired in site. Corroded sections are to be cut off and new sections are to be welded in place, Hand railing consists of 32 mm NB diameter tubing handrail stanchions, 32 mm NB diameter tubing handrail. Petrolatum primer corrosion prevention spray coatings are to be applied on the inside of repaired handrails. - Before the application of paint, the areas to be painted shall be cleaned of all oil, grease, salt and contaminants by the use of a high-pressure steam cleaner, or by using a high-pressure washer (minimum of 250 bar) in conjunction with a suitable water based biodegradable degreaser and thereafter left to dry. - Where required, the bulk of the oil and grease on the areas to be prepared and painted will have to be removed by scraping and solvent cleaning prior to high pressure cleaning. - Corroded areas shall be mechanically prepared to bare bright metal (ST-3, or greater) to ensure that all corrosion has been removed. The surrounding areas of localised corrosion are to be further prepared by feathering to ensure paint blending. All prepared areas are to be immediately painted with a suitable primer to prevent the area from oxidising. - Surface preparation and painting to be done in accordance with TPT specification EEAMQ-008 rev 17. Should a bidder wish to offer coating system other than those specified, as an alternative, the bidder shall submit full technical details and a list comparing all appropriate details of the alternatives proposed, with the original specified. - Remove and replace damaged Cowley Fan covers and Cabin Air Cooling System The installed Cowley Fan covers and Cabin Air Cooling must be of the High resistant material, same dimensions as the removed Cowley Fan covers and Cabin Air Cooling System. Location of service: TPT-Pier 1. 源: ONLINE TENDERS

Ngwathe Local Municipality hereby invites service providers to submit formal written quotations on the following: Request for hiring of heavy duty vehicle - TLB for 20 days Edenville. 源: ONLINE TENDERS

Quotations are hereby invited for the following: Supply of electrical cable. Specifications: - 6 x Cable, electrical; type: hybrid lift, conductor quantity: 17 core, potential: 600V, current: 61 a, length: 40m, covering: flexible rubber insulation; P/N: 3002198-500, Alimak Hek Group AB; Liebherr STS crane passenger lift conductor, diameters: 4 x 10mm², 1 x 2 x 2.5mm², 3 x 3 x 1mm², 2 x 1mm². Required at: Cape Town Container Terminals. 源: ONLINE TENDERS

Ngwathe Local Municipality hereby invites service providers to submit formal written quotations on the following: Request for hiring of heavy duty vehicle - Tipper truck x 2 for 20 days Heilbron. 源: ONLINE TENDERS

Quotations are hereby invited for the following: Rental of parkhome: 6m x 18m: messroom for a once off period. Scope of works: - Procure specified parkhomes; - Deliver parkhomes to final agreed location; - Covered walkways; - Electrical connections; - Sewerage connections; - Certificate of Compliance (CoC’s). 源: ONLINE TENDERS