Pulmonary specialists services (投標 №92646495cn)

請註冊

分享這個:
國家: Italy
語言: EN IT
顧客:
數: 92646495
出版日期: 17-10-2023
源:
用原始語言描述

描述

有關招標的全部信息已關閉。
有關該站點的更多信息,請閱讀以下信息。

關於我們

俄羅斯和世界範圍內招標和採購的領先搜索引擎

  • 俄羅斯和世界上最大的招標和採購來源數據庫
  • 根據您的設置免費提供每日新聞
  • 您需要的格式的中標者信息
  • 方便顯示和上傳信息

選擇我們

入門

在站點上註冊,之後您可以使用以下站點功能:

  • 為您的關鍵短語訂閱免費郵件列表
  • 查看招標公告
  • 以Excel格式導出摘要信息
  • 查看有關標書的中標者,供應商和客戶的部分信息

登記表

要使用網站的所有功能並查看全部信息,您需要註冊一個商業帳戶

  • 選擇關稅
  • 以任何可能的方式付費進行訪問

完全訪問
Re-Advertisement of Tender Number: ARC/05/08/2023. Bids are hereby invited for the following: Appointment of a service provider for the renewal and installation of the existing industrial cold and freezer rooms. Scope: The following work is required at the ARC-AP/Irene abattoir. The abattoir has about 6 industrial cold rooms and 2 industrial freezer rooms. The cooling units have aged and not working and need replacement. There are some repairs that are required on the cold rooms. The major work needed is as follows: - New electrical wiring according to watt usage (mains); - Remove old distribution boards in the deboning and processing area; - New insulated piping system (hard copper) from compressors to the rooms; - Piping insulation shall be of Armaflex type as specified. Armaflex insulation to all systems shall be at least 25 mm thick; - All condensate drainage from evaporators are to be piped to the nearest condensate drain points; - Installation of new condensing units and evaporator units into 7 cold rooms and 4 freezer rooms; - The condensing units and evaporator units should be able to cater to at least 10% more volume of the specified room; - Installation of alert systems (Remote Temperature Monitoring Device) in 9 rooms when temperature is changing; - Installation of the extraction fans in the compressor rooms; - Remove the old door rubbers from 13 doors and install new silicone rubbers and align the doors properly; - General repairs of the cold and freezer rooms (e.g. fastening of loose bolts, alignment of the door rails etc.); - Repair 12 door safety lock mechanism; - Installation of Clear PVC strip curtains in walk in cold rooms and freezer rooms and also at the entrances of the abattoir and Meat Technology area; - Closing of spaces above 4 door chillers; - Paint inside of the cold rooms with food grade paint; - Test the entire installation. Contract period: The work needs to be completed in a period of six weeks. 源: ONLINE TENDERS

Architectural, construction, engineering and inspection services 源: TED

Immunosuppressive agents 源: TED

Technical automobile inspection services 源: TED

Repair, maintenance and associated services related to railways and other equipment 源: TED

Plastering work 源: TED