Quotations are hereby invited for the following: Supply and deliver batteries. Specification: Supply and deliver: 1. Battery 9 volt, unit of measure: Each, qty: 200: - Battery 9v Ultralife lithium, - Average voltage: 9v, - Non-rechargeable, - Nominal capacity: 1.2Ah Max, - Continuous discharge: 150mA, - Pulse capacity: 1A, - 5 years shelf life, - Delivery period: 7 to 21 days, 2. Battery AA Alkaline, unit of measure: Each, qty: 400: - AA Battery capacity (Avg): Alkaline: 2500 mAh, - Operating temperature: 0°C - 60°C, - Diameter: 14.5mm, - Height: 50.5mm, - Chemistry: Alkaline, - Delivery period: 7 to 21 days, 3. Battery R14, unit of measure: Each, qty: 100: - R14 size battery 1.5V, - Super Alkaline, - 5 years shelf life, - Delivery period: 7 to 21 days, 4. Battery AAA 1.5v, unit of measure: Each, qty: 400: - Alkaline AAA battery nominal voltage: 1.50 volts, - Alkaline AAA battery capacity (Avg) - Alkaline: 1200 mAh, - Alkaline AAA battery operating temperature: 0°C - 60°C, - Alkaline AAA battery diameter: 10.5mm, - Alkaline AAA battery height: 44.5mm, - Chemistry: Alkaline, - Shelf life: 5 years, - Delivery period: 7 to 21 days. Institution Name: Benedictine Hospital. Province: KwaZulu-Natal. Department of entity: Department of Health. Division or section: Supply Chain Management. Place where goods/service is required: Main Stores. Contract period (if applicable): Once off. (投標 №104488296cn)

請註冊

分享這個:
國家: South Africa
語言: EN
數: 104488296
出版日期: 16-05-2024
源:

描述

有關招標的全部信息已關閉。
有關該站點的更多信息,請閱讀以下信息。

關於我們

俄羅斯和世界範圍內招標和採購的領先搜索引擎

  • 俄羅斯和世界上最大的招標和採購來源數據庫
  • 根據您的設置免費提供每日新聞
  • 您需要的格式的中標者信息
  • 方便顯示和上傳信息

選擇我們

入門

在站點上註冊,之後您可以使用以下站點功能:

  • 為您的關鍵短語訂閱免費郵件列表
  • 查看招標公告
  • 以Excel格式導出摘要信息
  • 查看有關標書的中標者,供應商和客戶的部分信息

登記表

要使用網站的所有功能並查看全部信息,您需要註冊一個商業帳戶

  • 選擇關稅
  • 以任何可能的方式付費進行訪問

完全訪問
Логик контроллер PLC-ийн CPU худалдан авах /Шатахуун хангалтын алба/ 源: Төрийн худалдан авах ажиллагааны цахим систем

Аэродромын цэвэрлэгээ үйлчилгээний троссон шүүр болон плугны резин 源: Төрийн худалдан авах ажиллагааны цахим систем

Сумын цахим танхим байгуулах 源: Төрийн худалдан авах ажиллагааны цахим систем

RELOCATION WORKS FOR SOFT LANDSCAPE for Northern area Municipality Gardens and road 源: Tender Board - Kingdom of Bahrain

Supply of Bently Nevada Machine Condition and Monitoring Modules for the new 1HCU Wash Water Injection Pumps P7704A and P7704B 源: Tender Board - Kingdom of Bahrain

Eskom Holdings SOC Ltd (hereinafter “Eskom”) invites you to submit a tender for the following: Inspection and repairs of ducting on units 1, 2, 4, 5 and 6 during planned outages for Duvha Power Station. The scope of modification is as follows: • Full inspection and submit report; • Grease bearings and ball joints on links; • Remove bearing stuffing box cover, clean shaft, repack & box up bearing stuffing box; • Fit new packing on all ducting inspection doors; • Replace flue gas damper doors, shafts, shaft pins, frames, divisional plates, bottom supports, 30mm square bars, 80 x 6mm seals on doors, bearings, links including mechanical settings after replacements. Doors to be collected from the stores by the contractor; • Replace all 30mm square bar sealing strips on flue gas damper; • Replace all 80 x 6mm seals on the flue gas damper doors; • Mechanical, electrical stroke checking and settings of all dampers; • Clean all debris and ash pile up within the ducting including FD fan intake screens using plastic bags; • Cut access Holes and install handrails around the holes 2500 x 1500 meters, replace after completion of internal work; • Open access doors; • Replace 6mm - 10mm thick eroded plate by welding new; • Replace 12mm - 16mm thick eroded plate by welding new; • Repair grease pipes & nipples; • Close access doors; • Vertical weld repairs on 6 - 10mm plate; • Vertical weld repairs on 12 - 16mm plate; • Horizontal weld repairs on 6 - 10mm plate; • Horizontal weld repairs on 12 - 16mm plate; • Replace bearings; • Replace 80 x 80mm angle iron Stiffeners; • Replace 100 x 50mm channels in front of doors, position of channel to be in line with 100% open door position; • Replace 100, 120, 250, 300mm x 6mm protection plates; • Replace 80Nb stays with 100 x 10mm protection (protection plate), Unit 1, 2, 4, 5 and 6 vanes: • Replace 1650 x 520 x 6mm deflector vanes and 1650 x 25 x 10mm flat bar protection (Top); • Replace 1500 x 260 x 6mm deflector vanes (middle); • Replace 1645 x 480 x 6mm deflector vanes (bottom); • Replace 1650 x 25 x 10mm deflector vanes (top). Economiser outlet to A/H inlet: • Replace 6mm-10mm thick eroded plate by welding new; • Replace 10mm-16mm thick eroded plate by welding new; • To fit 196 50mm socket and plugs; • Deflector plate 1200 x 2500mm; • Repair 25 x 10mm Dividing walls protection; • Replace round bar on ducting access ladders; • Remove and replace 16mm, 25mm round stainless steel thermocouples pockets with protection; • Replace 80 x 6mm seals on the flue gas damper; • Replace 35mm square bar sealing strips on the flue gas dampers; • Fit new packing; • Cut and replace 60 x 6mm wide expansion joint sections; • Attach chains and damps to hanger rods; • Replace cell inlet damper stainless steel seals; • Replace cell inlet damper 40 x 40 x 6mm angle iron; • Replace 120 x 75mm round shaft on the flue gas damper. 源: ONLINE TENDERS