在屋頂和屋頂工作: 招標、公共採購 2025




請註冊

分享這個:
只: 8
03 nov
Quotations are hereby invited for appointment of a suitable, qualified and experienced professional service provider to draft building plans for Alternative Building Technology (ABTS) houses for future development of emergency housing in the municipality (WC024). Scope: The scope of work to be carried out by the Professional Service Provider shall consist of providing building plans that will be utilized as the standard for all ABT housing projects in the WC024. It is important to note that the ABT houses will have the following dimension options: • A single 40m² unit with a bathroom inside; • A single 40m² unit without a bathroom inside; • A semidetached 80m² unit with two bathrooms for each family; • A single 24m² unit with a bathroom inside; • A single 24m² unit without a bathroom inside. The building plans for each size should contain, but not be limited to, the following: • Roofing - IBR AZ150 hot-dipped galvanized roof sheeting, roof trusses pitch between 7 - 11 degrees with 0-300 mm overhangs on the eave and 0 mm on the gable ends; • Ceilings - 6 mm nailed-up PVC ceilings, minimum floor to ceiling height 2,400 mm; • 1 x lockable door per room; • Wall panels - to be +-40 mm thick, door frames are to be adequately bolted to walls. Wall panels to have a minimum vertical load bearing capacity of 1 ton in the centre and 1.8 tons on the seam between two panels; • 1 x (900 mm x 900 mm) anodized aluminium window with glass insert per room (E.g. 1 in the bathroom, 1 in the bedroom, 1 in the open plan lounge and kitchen); • Plug sockets 1 per room, double Shuko plug sockets, lear or similar equivalent (16 Amp), 4x4 double; • Light fittings: Ceiling-mounted 4 ft single or double open channel v-shape waterproof 1.2; • Meter fluorescent lights, ceiling-mounted bowl fittings JD 90 lights or equivalent in bathrooms, external bulkheads IP44 circular 16w 2D external round bulkhead with porcelain KO or equivalent; • Sanitation and plumbing, each modular unit must have 1 x bathroom with the following: 1 flushable ceramic toilet and minimum 9L cistern complete with toilet seat and all plumbing connections, 1 x white porcelain, wash hand basin with pedestal or similar design, 1 x pillar tap with cold function, 1 x single SS304 kitchen sink, single bowl, single drainer drop in stainless steel +-L 750 mm x 400 mm with 1 tap and waste plumbing connection, a sink to be installed in the kitchen; • Load bearing capacity of the floors are rated at +/- 250kg/m². The floor chassis must be galvanized and bolted together with suitable floorboards and vinyl sheeting covering, slip resistance – EN 13893 Class DS. (EN) 添加到收藏夾
顧客: ONLINE TENDERS

數: 131874741

國家: South Africa

源: ONLINE TENDERS

02 apr
Quotations are hereby invited for the following: Replaced damaged roof at Paarl squash club. Scope of work: 1. Contractor to remove existing damaged roof sheets (approximately 335m²) and asbestos rainwater goods (approximately 36rm): a) Contractor to carefully remove existing ridge capping and put aside for re-use once new corrugated roof sheets has been installed. b) Contractor to carefully remove existing roof sheets as indicated on drawing A1 (approximately 350 m²). c) Contractor to carefully remove existing asbestos gutters and downpipes (approximately 36 RM). d) Contractor to carefully inspect roof structure for any damaged timber and replace with new timber, SABS approved purlins/rafters in order to re-enforce roof. e) All materials, debris and rubbish to become the property of the contractor and will the contractor be responsible for disposal. Contractor will be responsible for carting and dumping of these materials and ensure that site is clean and unencumbered. 2. Supply and Installation of New 0.5mm IBR Roof sheets, Flashings fixed to existing purlins: a) Contractor to carefully inspect roofing structure for any damaged rafters, battens and purlins. b) Contractor to inform employer agent of intention to remove timber from roof structure for replacement. c) Contractor to replace damaged timber in Roof structure with SABS approved materials and must install according to manufacturer’s specifications and guidelines. d) Supply and Install new IBR 0.5mm galvanised coated z275 roof sheets (approximately 350 m² in continuous lengths) strictly to be laid on existing 76X 50mm SAP purlins at 900 ccs, all to be done to manufacturer’s instructions, guidelines and specifications. SANS 0400 Rules and regulations Part L for Roofs (335m²) is applicable, min 150mm overlapping of roof sheets to be strictly maintained at all times. Note: Alignment of purlins to be checked and corrected before placing of new roof sheets. e) Contractor to Supply and install new galvanised ridge capping approximately 28m, along the peak of the roof with overlaps (approximately 250mm either side). f) Install new 0.4 mm 100x25mm Heunis steel cover flashing or similar, at vertical and horizontal intersection points, strictly to manufacturer’s specifications and guidelines. g) “Rain Tite Waterproofing Compound Sika Raintite Membrane” or similar product to be applied strictly to manufacturers guidelines and specifications. Note: End laps/side laps to be treated with approved self etching primer. All surfaces must be clean, sound, dry and properly cured before applying waterproofing product. 3. Supply and Install Seamless Aluminium Rainwater Goods (approximately 39rm): a) Contractor carefully inspect the area to familiarise themselves with, and carefully remove existing asbestos gutters and downpipes. b) Contractor to supply and install seamless aluminium gutter system including all stop ends, brackets, beams etc. All seams and joints to be sealed to prevent leaking. (EN) 添加到收藏夾
顧客: ONLINE TENDERS

數: 102126776

國家: South Africa

源: ONLINE TENDERS