Quotations are hereby invited for the hiring of a specialized double axle combination unit truck for the cleaning of six (6) wastewater pump stations in the municipal area. Specifications: Hiring of a specialized double axle truck for the cleaning of 6 wastewater pump stations in the Hantam Municipal Area: - Calvinia X 3 pump stations; - Nieuwoudtville X 2 pump stations; - Loeriesfontein X 1 pump station. Water and waste tank: - Material: 3CR12 Stainless Steel; - Water tank capacity: 8 000L; - Waste tank capacity: 7 000L; - Dumping: 40”; - Rear Door: Top hinged hydraulic full opening; - 4” drain valve: Discharge of liquids (Sludge & debris strays behind); - 6” drain valve: Total discharge; - Sight glasses: Monitor water and waste levels. Vacuum system: - Blower: Robuschi (Italy); - Air flow: Moves 1055 litres of free air per second; - Maximum distance: Up to 50m; - Maximum depth: Solid H20 lift = 9.1m; With airlift >20m; - Exhaust silencer: Noise reduction; - Vacuum arm: Top mounted with 240 degrees rotation; Hydraulic lifting and lowering of vacuum hose. High pressure water system: - Water Pump: Pratisolli MK65 (Italy); - Water Flow: 406L per minute; - Maximum jetting distance: 200m; - Pressure: 150 bar; - Input speed: 1800 RPM. Operating personnel: - Operator/Driver: Operates vacuum and high-pressure water system; - Assistant: Handles the vacuum & jetting hose; - Standard PPE: Two piece overall, hard-hat, safety glasses, safety boots, steel toe gumboots (wet conditions), gloves, earplugs, respirator masks. Standard operating equipment: - Vacuum hose: 4” / 6” x 20m; - Discharge hose: 4” x 10m; - Fire hose: 10m; - High Pressure jetting hose: 120m; 300bar - Bomb nozzle: Removing large quantities of sand (Pipe diameter >300); - Retro nozzle: Breaking of blockages; - Pointer: Breaking of blockages; Removing of fine roots; - Shovel: 1; - Pick: 1. Standard safety equipment: - Fire extinguisher: 1; - Cones: 4 x 750; 2 x 450 ; - Tri Angle: 1; - Gas detector: 1; - Medical kit: 1; - Waders: Each assistant. (EN) 添加到收藏夾
顧客: ONLINE TENDERS

數: 118405309

國家: South Africa

源: ONLINE TENDERS

04 feb
Quotations are hereby invited for the repair and maintenance of the wastewater treatment plant in Loeriesfontein. Scope of Work: Inlet screen: • Not applicable; Electrical Supply System: • Check that all electrical cables & connections are intact and free of damage; • Check that Distribution Board/Control Panel Switches, Indicator Lights, Controls, Circuit Breakers, Contactors and overload protections are operational and test functionality where applicable; • Clean control panel and trunking and remove dust build up and any other materials Air Supply System; • Check all blowers for damage/wear or lubrication requirement; • Cleaning of Air Filter as required and replace quarterly; • Check all valves, relief valves, pressure gauges and piping for wear/damage and repair/replace as required; • Visually inspect bioreactor tanks to verify air supply to bioreactors; Re-Activated Sludge Return: • Check functioning of all valves; • Check if sludge return is functioning properly from all clarifier tanks; • Remove sludge return pumps visually inspect and check for any obstructions in the impellers; • Check sludge levels in all tanks and de-sludge if required; • Check dosing pump operation and settings and replace bacteria if required; Disinfection System: • Check operation of Ozone generators; • Measure air flow and maintain all pumps, Valves and components as per OEM Guideline; General/Process Operation: • Record whether the Plant been regularly maintained with respect to general cleanliness and preventative maintenance; • Are there any floating materials in any of the tanks; • What is the colour of the mixed liquor; • Is there a bad smell around the Sewage Treatment System; • Is there any floating sludge in the settler tanks; • Re-Train the relevant personnel during the service of the Plant; • Issue a report on the findings during the service on the Plant along with analysis results; Exclusions: • Any repairs on equipment; • Electrical component repairs; • Piping and Fittings repair. (EN) 添加到收藏夾
顧客: ONLINE TENDERS

數: 118405312

國家: South Africa

源: ONLINE TENDERS

02 feb
Addendum: Extension of Closing Date and Amendment to Proposal Documents. Proposals are hereby invited for the impact study for network infrastructure – proposed Private Sector Participation (PSP) for optical fibre network, with consideration of the national rail policy and the recently enacted economic regulation of transport act, within a period of four (4) months. The following paragraphs detail the scope of work required for this demand request: a) They own, operate, and manage telecommunications network infrastructure which is key to safe and reliable freight operations. b) The networks have primarily been deployed for the support of the mission critical systems deployed for the safe movement of trains and pumping control operations of fuel. The fibre network is deployed to ensure connectivity of Relay rooms for the support of the Train Authorization Systems (TAS). In addition to the TAS the fibre optic cable is also responsible to connect Condition Assessment Systems (CAS), Tele-control for substations and Telecommunication High sites. c) The products that are in scope for the proposed PSP is the Optic fibre cables and DWDM. The following paragraph detailed these networks: - The fibre transmission network is made up of more than 9000km of optic fibre cable (Layer 1). TFR’s Layer 1 network consists of 24 – core, 36 – core, and 48 – core fibre cables. - The DWDM Optical Transport Network (Layer 2) provides multiplexing capability of bandwidth services across the Layer 1. The network is supported by over 140 network equipment rooms with approximately 159 Huawei Dense Wavelength Division Multiplexers (DWDM) nodes used for transmitting digital signals. d) Note that there is no common CMDB (Configuration Management Database) for fibre assets: - Resources and tools of trade dedicated to supporting and maintaining the above-listed elements. e) The TPL-owned fibre transmission is made up of 715Km of fibre: - Layer 1: (Passive fibre): 1 x 48 Core – mainly unused (~2 Pairs used) for IT and security services: “Semiexpress” route terminating only at pump stations: included in scope 1 x 24 Core for TPL process network, fully owned and operated by TPL (OT): “Omnibus” route terminating and valve and pump stations: excluded from scope. f) Maintained by TFR. - Layer 2: (Active fibre): • Optical equipment (Layer 2): Cisco Multi-Services-Provisioning-Platform. • End Of life: Support agreement ended in 2019. • Supported on time and material basis. • Monitored from Master Control Centre (MCC) at Durban. g) The other network that is deployed for Train safety is the radio network that consist of the Trunked and conventional radio networks. These networks are out of scope for the proposed PSP. (EN) 添加到收藏夾
通過申請結束: 2 天
顧客: ONLINE TENDERS

數: 118264969

國家: South Africa

源: ONLINE TENDERS